7. Own Port: The Port number to communicate on
8. Remote IP Address: the IP Address the Discovery is sending its data to, in
case the unit is configured as Client or UDP.
9. Remote Port: The remote port
10. Subnet Mask: Enter The Subnet mask
11. Gateway: The gateway to communicate through. Enter 0.0.0.0 if not used
12. Connect Mode, there are 3 options:
-
TCP Client: The Discovery tries to connect to the remote IP Address +
Port, using TCP
-
TCP Server: The Discovery waits for a client to connect, using TCP
-
UDP: uses the connectionless datagram protocol
13. Other settings: The Ethernet module has many more settings than the ones
above. This option determines what to do with those, when saving the
above settings
Leave unmodified: When saving the above settings, all other settings are
left unmodified. To be used if customer-specific Ethernet settings are used.
Discovery defaults: When saving the above settings, all other settings are
returned to Scantech factory defaults.