SCANTECH ID (Champtek company) Discovery SG-20 User Manual
Page 68
Ethernet Configuration
60
3. Once in the Configuration Mode, you reach the Service Screen to set the
Ethernet parameters by subsequently pressing buttons 3 and 1.
4. When now selecting button #3, the unit’s Ethernet Settings will be retrieved
from the Ethernet converter module, before going to the next Service
Screen.
5. When leaving this menu, you will be prompted to store these settings into
the Ethernet module. If yes, the Discovery will compare the RS-232 settings
of both the Discovery as well as the Ethernet module. If not identical, you
will be asked to synchronise them.
ATTENTION
You can use:
Button #1 to select the next field:
Button #2/3 to in/decrease:
(auto-accelerating) and
Button #4 to go back:
6. Own IP Address: The IP Address the Discovery will use. Enter 0.0.1.0 to
obtain an address through DHCP