SCANTECH ID (Champtek company) Discovery SG-20 User Manual
Page 49

Scantech-ID Discovery SG-20
41
- Ethernet (optional, see page 60).
ATTENTION
1. As of partnumber A360104) the interface can be selected by
using this menu. Previous versions use jumpers on the main
board (Chapter 4.1”Interfaces”).
2. The Ethernet interface is optional and is only available if an
Ethernet module is placed inside the Discovery.
3. All interfaces use the same port on the back of the Discovery. If
switched from Ethernet to another interface, the Discovery
should be opened to bypass the Ethernet module.
Screen 3.1.2
Select next field
Increase value of current field
Decrease value of current field
Back to screen 3.1
RS485 Settings :
Address
: The RS485 address (1 - 32)
Protocol
: - Standard
: The standard RS485 protocol
- Enhanced : A slightly enhanced protocol, decreasing
network traffic.
Terminator
: Enables or Disables the termination resistor. Should only
be used on the last physical Discovery in the network.