SCANTECH ID (Champtek company) Discovery SG-20 User Manual
Page 50

Ethernet Configuration
42
Screen 3.2
Select Port number (1 - 4)
Select next field
Increase value of current field
Back to screen3.0
This screen shows the internal port settings.
The Discovery has 4 internal RS232 ports:
Port 1:
The main port, through which all communication with a host is performed. This
port can be configured as RS232, RS422, RS485 or RS232 using TTL levels.
Port 2:
RS232 port for a hand held scanner. As of partnumber A360104, this port can
be accessed from the backside of the Discovery. This port is input only and
cannot be modified in any way. Its fixed settings are :
-
9600,8,N,1
-
Echo : Off
-
Suffix : CR (the last character of a barcode sent to a host)
-
RTS/CTS : On
Only the 'Device' option can be altered:
Device:
- Hand held:
Use for hand held scanner.
- None:
Entirely ignore this port.
Port 3:
This port is connected to the internal barcode scanner. Every option, except
RTS/CTS, can be altered.
Explanation:
Suffix:
The last character(s) the device uses after its
messages.