beautypg.com

Ommand, Escriptions – B&B Electronics ZXT9-RM-KIT - Manual User Manual

Page 70

background image

Document Number: pnZXTxRM-0712m

Page
70

Security

RO

0x21 (33d)

Packetization Timeout

0 - 0xFFFF [x UART
character time]

Serial
Interfacing

2

3

RP

0x22 (34d)

RSSI PWM Timer

0 - 0xFF [x 100 msec]

Diagnostics

1

0x20 (32d)

RR

0x18 (24d)

Retries

0 - 0xFF

Networking &
Security

1

0x0A (10d)

RT

0x16 (22d)

GPI1 Configuration

0 - 2

Serial
Interfacing

1

0

SB

0x37 (55d)

Stop Bits

0 - 1

Serial
Interfacing

1

0

SH

0x25 (37d)

Serial Number High

0 - 0xFFFF [read-only]

Diagnostics

2

varies

SL

0x26 (38d)

Serial Number Low

0 - 0xFFFF [read-only]

Diagnostics

2

varies

SM

0x01 (1d)

Sleep Mode

0 - 8 (3 is reserved)

Sleep (Low
Power)

1

0

ST

0x02 (2d)

Time before Sleep

(ATAT+3) - 0x7FFF [x 100
msec]

Sleep (Low
Power)

2

0x64 (100d)

TP

0x38 (56d)

Board Temperature

0 - 0x7F [read-only]

Diagnostics

1

-

TR

0x1B (27d)

Delivery Failure Count 0 - 0xFFFF [read-only]

Diagnostics

2

0

TT

0x1A (26d)

Streaming Limit

0 - 0xFFFF [0 = disabled]

Networking &
Security

2

0

TX

0x3F (63d)

Transmit Only

0 - 1

RF Interfacing

1

0

VL

-

Firmware Version -
verbose

Returns string

Diagnostics

-

-

VR

0x14 (20d)

Firmware Version

0 - 0xFFFF [read-only]

Diagnostics

2

-

*Firmware version in which the command was first introduced (firmware versions are numbered in hexadecimal notation.)

6.4.2.1

Command Descriptions

Command descriptions in this section are listed alphabetically.
Command categories are designated within "< >" symbols that follow
each command title. Zlinx Xtreme Radio Modems expect parameter
values in hexadecimal (designated by the "0x" prefix).