3.3.2 Water Tight Threaded Conduit Installation
1. Insert the treaded end of the body into the conduit knock-out from the outside of the
enclosure. The rubber gasket should be on the outside of the enclosure.
2. Thread the Nut onto the conduit body from inside the enclosure.
3. 1/2 and 3/8 inch conduit fittings as well as 1/2 Inch, rigid, threaded conduit can be
attached to the threaded hub.
3.4 IP67 Membrane Cable Gland
NOTE: the Cable Glands cannot be used for Class 1 Division 2 applications. Please see
the Quick Start Guide for UL Class 1 Division 2 installation instructions.
3.4.1 Description
The membrane cable gland is used to plug an unused hole in the enclosure.
Figure 3-7
IP67 Membrane Cable Gland
3.4.2 IP67 Membrane Cable Gland Installation
1. Stuff the cable gland into the knock-out hole with the narrow end toward the inside of
the radio modem enclosure. The enclosure wall will fit into the indentation between
the inside and outside portions of the gland.
3.5 Supplied Antenna
3.5.1 ZXT9-RM Supplied Antenna
Your Zlinx Xtreme 900 MHz product comes supplied with a “rubber duck” style antenna
which can be articulated up to 90 degrees. Then antenna is a ¼ wave dipole with an omni
directional pattern and vertical polarization. It is recommended that your Zlinx Xtreme
product be mounted vertically.