B&B Electronics ZXT9-RM-KIT - Manual User Manual
Page 56

Document Number: pnZXTxRM-0712m
Page
56
D7
– DIO7 Configuration: Configure options for the DIO7 line of the
module. Options include: CTS flow control. This is a pull down option.
Selections are:
0
– Disable
1
– CTS Flow Control
D6
– DIO6 Configuration: Configure options for the DIO6 line of the
module. Options include: RTS flow control. This is a pull down option.
Selections are:
0
– Disable
1
– RTS Flow Control
D5
– DIO5 Configuration: Configure options for the DIO5 line of the
module. Options include: Associated LED indicator (blinks when
associated). This is a pull down option. Selections are:
0
– Disable
1
– Associated Indicator
P0
– PWMO Configuration: Select/Read function for PWM0. This is a
pull down option. Selections are:
0
– Disable
1
– RSSI
AP
– API Enable: Enables API mode. This is a pull down option.
Selections are:
0
– API Disabled
1
– API Enabled
2
– API Enabled with PPI
PR
– Pull Up Resistor Enable: Set/read bitfield to configure internal
pullup resistors status for I/O lines. 1=internal pullup enabled, 0=no
internal pullup. Bitfield map: Bit 7 - DIN (P3), Bit 6 - IO8/SLEEP_RQ
(P9), Bit 5 - DIO6/RTS (P16), Bit 4 - DIO0 (P20), Bit 3 - DIO1 (P19), Bit
2 - DIO2 (P18), Bit 1 - DIO3 (P17), Bit 0 - DIO4 (P11). The range is 0x0
to 0xFF
Diagnostics: Access diagnostic parameters.