7.0 Use Cases


With any RF system it is best to set up and bench test before field
installation.

7.1 Point-to-Point Serial

7.1.1 Use Case Parameters

Serial RS-232 wire replacement. RS-232, 115.2 kbps, hardware flow control (CTS/RTS).
900 MHz Radio Modem with encryption.

7.1.1.1

Setup Instructions

1. Wire your RS-232 devices and power as described in section three.
2. Connect to the modem using the USB port.
3. Configure both radio modems the same with the exception of the destination

address.

4. Remember to save your new settings by clicking on the update button.
5. On the Basic Modem Settings Tab, ensure ZXT9-RM is displayed in the

model number box


6. Select a unique channel number. This is the same for both radio modems.