beautypg.com

B&B Electronics ZXT9-RM-KIT - Manual User Manual

Page 55

background image

Document Number: pnZXTxRM-0712m

Page
55

SP

– Cycle Sleep Period: Set/read Cyclic sleep period for cyclic

sleeping remotes. Set SP on Coordinator to match End Device.
Coordinator will discard indirect messages after a period of 2.5*SP, set
Coordinator SP = 0 to send direct messages. Maximum sleep period is
268 seconds (0x68B0).
Range is 0x0 to 0x68B0.

DP

– Disassociated Sleep Period: Set/read sleep period for cyclic

sleeping remotes that are configured for Association but that are not
associated to a Coordinator. Maximum sleep period is 268 seconds
(0x68B0). Range is 0x1 to 0x68B0.

Serial Interfacing: Change modem interfacing options.

Figure 5-34 Serial Interfacing (ZXT24-RM)

BD

– Interface Data Rate: Set/read the serial interface baud rate for

communication between modem serial port and host. Request non-
standard baud rates with values above 0x80 using a terminal window.
Read BD register to find actual baud rate achieved. This is a pull down
option. Selections are:

0

– 1200

1

– 2400

2

– 4800

3

– 9600

4

– 19200

5

– 38400

6

– 57600

7

– 115200


RD

– Receive Packetization Timeout: Set/read number of character

times of inter-character delay required before transmission begins. Set
to zero to transmit characters as they arrive instead of buffering them
into one RF packet. The range is 0x0 to 0xFF.