Table 60), Attiny26(l) – Rainbow Electronics ATtiny26L User Manual
Page 123
123
ATtiny26(L)
1477B–AVR–04/02
Note:
a = address high bits
b = address low bits
H = 0 – Low byte, 1 – High Byte
o = data out
i = data in
x = don’t care
Table 60. Serial Programming Instruction Set
Instruction
Instruction Format
Operation
Byte 1
Byte 2
Byte 3
Byte4
Programming Enable
1010 1100
0101 0011
xxxx xxxx
xxxx xxxx
Enable Serial Programming after
RESET goes low.
Chip Erase
1010 1100
100x xxxx
xxxx xxxx
xxxx xxxx
Chip Erase EEPROM and Flash.
Read Program Memory
0010 H000
xxxx xxaa
bbbb bbbb
oooo oooo
Read H (high or low) data o from
Program memory at word address a:b.
Load Program Memory Page
0100 H000
xxxx xxxx
xxxx bbbb
iiii iiii
Write H (high or low) data i to Program
Memory page at word address b. Data
low byte must be loaded before data
high byte is applied within the same
address.
Write Program Memory Page
0100 1100
xxxx xxaa
bbbb
xxxx
xxxx xxxx
Write Program Memory Page at
address a:b.
Read EEPROM Memory
1010 0000
xxxx xxxx
xbbb bbbb
oooo oooo
Read data o from EEPROM memory at
address b.
Write EEPROM Memory
1100 0000
xxxx xxxx
xbbb bbbb
iiii iiii
Write data i to EEPROM memory at
address b.
Read Lock Bits
0101 1000
0000 0000
xxxx xxxx
xxxx xxoo
Read Lock bits. “0” = programmed, “1”
= unprogrammed. See
for details.
Write Lock Bits
1010 1100
111x xxxx
xxxx xxxx
1111 11ii
Write Lock bits. Set bits = “0” to
program Lock bits. See
for details.
Read Signature Byte
0011 0000
xxxx xxxx
xxxx xxbb
oooo oooo
Read Signature Byte o at address b.
Write Fuse Bits
1010 1100
1010 0000
xxxx xxxx
iiii iiii
Set bits = “0” to program, “1” to
unprogram. See
for details.
Write Fuse High Bits
1010 1100
1010 1000
xxxx xxxx
xxxi iiii
Set bits = “0” to program, “1” to
unprogram. See
for details.
Read Fuse Bits
0101 0000
0000 0000
xxxx xxxx
oooo oooo
Read Fuse bits. “0” = programmed, “1”
= unprogrammed. See
for details.
Read Fuse High Bits
0101 1000
0000 1000
xxxx xxxx
xxxo oooo
Read Fuse high bits.
“0” = programmed,
“1” = unprogrammed. See
for details.
Read Calibration Byte
0011 1000
xxxx xxxx
0000 00bb
oooo oooo
Read Calibration Byte o.