Sn threshold – Printronix Online Data Validator User Manual
Page 72
![background image](/manuals/268576/72/background.png)
Chapter 2
Configuring the Validator
72
SN Threshold
This menu item sets the SN (signal to noise) threshold used by the
validator to discriminate between high peak noise and actual bar
code transitions. Any reflectance transitions that are below the
threshold are ignored and considered noise.
You can set the SN Threshold to a value from 5 to 199.
The default is 70.
1.
Press
to take the printer offline and place the printer in
Menu mode.
2.
If necessary, press
↓ and
↵
at the same time to unlock the
↵
key.
3.
Press
until VALIDATOR displays.
4.
Press
↑ until SN Threshold displays.
5.
Press
+
or
–
to scroll through the values: 5 to 199.
The default is 70.
6.
Press
↵
to select the desired value.
7.
Press
↓ and
↵
at the same time to lock the
↵
key, then press
PAUSE
to take the printer offline.
8.
Press
PAUSE
again to put the printer online.
..
.
..
.