5 rs422 #5, 6 rs422 #6, 7 id type – EVS MulticamLSM Version 10.04 - January 2011 Configuration Manual User Manual
Page 82: Rs422 #5, Rs422 #6, Id type, 5 rs422, 6 rs422, 7 id
Issue
10.04.A
EVS
Multicam – Version 10.04 – Configuration Manual
EVS Broadcast Equipment SA – January 2011
74
3.16.5 RS422
#5
Possible values: Sony BVW75, XtenDD35, Odetics, VDCP, EVS AVSP, EVS IPDP,
Edit Rec, ---------
Default: Sony BVW75
3.16.6 RS422
#6
Possible values: Sony BVW75, XtenDD35, Odetics, VDCP, EVS AVSP, EVS IPDP,
Edit Rec, Touch Screen, ---------
Default: Touch Screen
Note
•
It is preferable to assign all EVS remotes to the first RS422 ports.
Avoid interleaving protocols and EVS remotes in this list.
•
The Touch Screen can only be assigned to RS422 port #6.
3.16.7 ID
T
YPE
Possible values: ID LSM (default) / UmID
Defines the type of clip ID used by RS422 protocols (XtenDD35, Odetics, Louth
VDCP, EVS AVSP) to identify clips:
•
ID LSM: It identifies clips using their page, bank, clip and camera number (ex:
245C).
•
UmID: It is another identifier that is either assigned by the protocol when
creating the clip (ex: CLP00001), or defined automatically by Multicam when
the clip is created using the EVS Remote Panel, or when the protocol doesn’t
specify this ID.
When it is defined by Multicam, the UmID is a coded ID (ex: 3x2QogRW) that
is unique for every clip created on any server, and is based on the serial
number of the server, and creation date and time of the clip.