Analyzing the captured data – ZyXEL Communications ACCESSING INTERNET & INTRANET omni series User Manual
Page 117

Diagnostics 105
beginning of data capture. The resolution of this timing information is
in 0.01 second intervals.
The following commands determine the kind of protocol data to be
captured by the EPA:
AT Command
Description
ATCDn
CD0
Disable the capture of D-channel protocols.
CD1
Enable the capture of D-channel protocols
(default).
ATCBn
CB0
Disable the capture of B-channel protocols
(default).
CB1
Enable the capture of B-channel protocols.
ATCCn
CC0
Disable the capture of DTE-DCE interface
protocols(default).
CC1
Enable the capture of DTE-DCE interface
protocols.
The EPA starts to capture data when the command ATCT is issued.
This capturing process will continue until the command ATC$ is
issued. The EPA maintains 8 Kbytes RAM as a ring buffer. In case
the buffer is full, the earliest data captured will be overwritten by the
latest data.
Analyzing the Captured Data
To view the analyzed result, use the command ATC$. For your
convenience, the relevant AT commands are summarized as follows:
Command
Description
ATCT
Clears buffer and starts the embedded protocol
analyzer. Captures data immediately and starts the
timer.