Security Functions 95

Level 1

Level 2

Level 3

Password Check

Yes

Yes

Yes

CPN Check OK
and S119.6=0

N/A

Call back

Prompts the
remote user
to enter call
back
number

CPN Check OK
and S119.6=1

N/A

Keep the
connection

for calling
back.

CPN unmatched

N/A

Disconnect

CPN not
Available

N/A

Call back using
the corresponding
pre-stored number

AT Commands

*G1 for
Type 1
*G3 for
Type 2

*G2 for Type 1
*G4 for Type 2

*G5 for
Type 2

Setting and Modifying Passwords

Up to 40 user passwords can be defined using the AT*Hn command,
where “n” represents the index to the entry. Numbers between 0-39
are accepted.

The corresponding 40 call-back numbers are defined by
AT&Zn=xxx command, where “n” represents the index to the entry,
and “xxx” represents the assigned call-back phone number. Any
character (ASCII 0-127) can be used in the password table, the
maximum password length is 8 characters for each entry.

Security functions are only accessible through AT commands in
terminal mode. A supervisory password is required for adding or
modifying entries. The default supervisor password is ZyXEL when
the TA is shipped from the factory. This supervisory password is sent
to the remote if Type 1 security is set at the remote end.

To modify the supervisor password, use AT*HS.