13.17. Hardware Monitor Settings

HWM_PollInterval

Polling intervall for Hardware Monitor which is the delay in milliseconds between reading of
hardware monitor values. Minimum 100, Maximum 10000.

Default: 500 ms

HWMMem_Interval

Memory polling interval which is the delay in minutes between reading of memory values.
Minimum 1, Maximum 200.

Default: 15 mins

HWMMem_LogRepetition

Should we send a log message for each poll result that is in the Alert, Critical or Warning level, or
should we only send when a new level is reached. If True, a message is sent each time
HWMMem_Interval is triggered If False, a message is sent when a value goes from one level to
another.

Default: False

HWMMem_UsePercent

True if the memory monitor uses a percentage as the unit for monitoring, False if it uses Megabyte.
Applies to HWMMem_AlertLevel, HWMMem_CriticalLevel and HWMMem_WarningLevel.

Default: True

HWMMem_AlertLevel

Generate an Alert log message if free memory is below this value. Disable by setting to 0.
Maximum value is 10,000.

Default: 0

HWMMem_CriticalLevel

Generate a Critical log message if free memory is below this value. Disable by setting to 0.
Maximum value is 10,000.

Default: 0

HWMMem_WarningLevel

Generate a Warning log message if free memory is below this value. Disable by setting to 0.
Maximum value 10,000.

Default: 0