Trane LO User Manual

Page 8

background image

8

UNT-IOM-6

R

7” falseback

T

8” falseback

Digit 40 Main Auto Circuit Setter GPM

0

None

A

0.5

B

0.75

C 1.0

D

1.5

E

2.0

F

2.5

G

3.0

H

3.5

J

4.0

Digit 41 Auxiliary Auto Circuit Setter GPM

0

None

A

0.5

B

0.75

C 1.0

D

1.5

E

2.0

F

2.5

G

3.0

H

3.5

J

4.0

Digit 42 Subbase

0

None

A

2” height

B

3” height

C4” height

D

5” height

E

6” height

F

7” height

Digit 43 Recessed Flange

0

None

A

Recessed flange

Digit 44 Wallbox

0

None

A

Anodized

Digit 24 Reheat

0

None

A

Steam

B

Hot water

Digit 25 Disconnect Switch

0

None

D

With disconnect

Digit 26 Filter

0

None

1

1” TA

2

1” TA pltd. media

3

1” TA + 1 extra

4

1” TA pltd. media + 1 extra

5

1” TA + 2 extra

6

1” TA pltd. media + 2 extra

7

1” TA + 3 extra

8

1” TA pltd. media + 3 extra

Digit 27 Main Control Valve

0

None

A

2 way, 2 pos., N.O. (25 psig)

B

3 way, 2 pos., N.O. (30 psig)

C2 way, 2 pos., N.C

. (25 psig)

D

3 way, 2 pos., N.C. (15 psig)

E

2 way, 2 pos., N.O. (50 psig)

F

3 way, 2 pos., N.O. (50 psig)

G

2 way, 2 pos., N.C. (50 psig)

H

3 way, 2 pos., N.C. (50 psig)

J

2 way, mod., Cv = 0.7 (50 psig)

K

3 way, mod., Cv = 0.7 (50 psig)

L

2 way, mod., Cv = 1.5 (50 psig)

M

3 way, mod., Cv = 1.5 (50 psig)

N

2 way, mod., Cv = 2.5 (50 psig)

P

3 way, mod., Cv = 2.5 (50 psig)

Q

2 way, mod., Cv = 4.0 (50 psig)

R

3 way, mod., Cv = 4.0 (50 psig)

Digit 28 Auxiliary Control Valve

0

None

A

2 way, 2 pos., N.O. (25 psig)

B

3 way, 2 pos., N.O. (30 psig)

C2 way, 2 pos., N.C

. (25 psig)

D

3 way, 2 pos., N.C. (15 psig)

E

2 way, 2 pos., N.O. (50 psig)

F

3 way, 2 pos., N.O. (50 psig)

G

2 way, 2 pos., N.C. (50 psig)

H

3 way, 2 pos., N.C. (50 psig)

J

2 way, mod., Cv = 0.7 (50 psig)

K

3 way, mod., Cv = 0.7 (50 psig)

L

2 way, mod., Cv = 1.5 (50 psig)

M

3 way, mod., Cv = 1.5 (50 psig)

N

2 way, mod., Cv = 2.5 (50 psig)

P

3 way, mod., Cv = 2.5 (50 psig)

Q

2 way, mod., Cv = 4.0 (50 psig)

R

3 way, mod., Cv = 4.0 (50 psig)

Digit 29 Piping Package

0

None

A

Ball valve supply & return

B

Ball valve supply & manual circuit

setter return

CBall valve supply & auto circuit

setter

D

Ball valve supply & return

w/strainers & unions

E

Ball valve supply & manual circuit

setter w/strainers & unions

F

Ball valve supply & auto circuit

setter w/strainers & unions

Digit 30 Control Type

A

Fan Speed Switch

CTUC

D

TUC w/Trane ICS

E

Tracer

®

ZN.010

F

Tracer

®

ZN.510

G

Tracer

®

ZN.520

Digit 31 Control Options

D

Unit mtd. fan mode switch (OHML)

K

Wall mtd. fan mode switch (OHML)

V

Unit mtd. zone sensor, w/SP

rotary, & fan mode switch

(OAHML),

W

Wall mtd. zone sensor w/

SP rotary, & fan mode switch

(OAHML),

X

Unit mtd. fan mode switch, wall

mtd. setpoint dial zone sensor

Digit 32-34 Future Control Options

Digit 35 Control Function 3

0

None

2

Condensate overflow detection

Digit 36 Control Function 4

0

None

2

Low temperature detection

Digits 37 & 38 Future Control Options

Digit 39 Recessed Options

0

None

A

Stand. 5/8” recessed panel

B

2” projection panel

C2.5” projection panel

D

3” projection panel

E

3.5” projection panel

F

4” projection panel

G

4.5” projection panel

H

5” projection panel

J

5.5” projection panel

K

6” projection panel

L

2” falseback

M

3” falseback

N

4” falseback

P

5” falseback

Q

6” falseback

K

4.5

L

5.0

M

6.0

N

7.0

P

8.0

Q

9.0

R

10.0

T

11.0

U

12.0

K

4.5

L

5.0

M

6.0

N

7.0

P

8.0

Q

9.0

R

10.0

T

11.0

U

12.0