Quantum Data 801GC User Manual
Page 288

6-162
Chapter 6: Programming
Model 801GC, 801GF & 801GX¥Rev. A
SEQN
SEQuence New
Classification:
Sequence editor control
Command Syntax:
SEQN [
Limits:
(8 characters minus any extension)
Query Syntax:
SEQN?
Query Response:
Description:
The SEQN command initializes the sequence edit buffer. The
name
will return the name that has been assigned as the sequence’s
name.
Other Required Cmds:
None
E x a m p l e s :
S E Q N / / I n i t e d i t b u f f e r w i t h o u t
/ / a s s i g n i n g a n e w n a m e
or
S E Q N M Y _ S E Q / / I n i t e d i t b u f f e r w i t h
/ / n a m e o f " M Y _ S E Q "
SEQP
SEQuence Path
Classification:
Sequence memory management
Command Syntax:
SEQP
Limits:
(8 characters minus any extension)
Query Syntax:
SEQP?
Query Response:
Current sequence path name
Description:
The FMTP command sets the current image path name to a
given directory. The query will return the current image path
name.
Other Required Cmds:
None
Example:
S E Q P B U R N / / S e q u e n c e s i n B U R N d i r e c t o r y
/ / w i l l b e l i s t e d