KEYY
KEY toggle
Classification:
System parameter setting
Command Syntax:
KEYY
Limits:
1 = Image (/Step) version
2 = Red gating
3 = Green gating
4 = Blue gating
5 = ACS gating
6 = DCS gating
7 = DSS gating
8 = Outputs gating
Query Syntax:
None
Description:
The KEYY command can toggle the status of the following items:
Image version of the currently displayed image, Red, Green
and Blue video gating, ACS / DCS / DSS Sync gating and Outputs
gating. The order of the buttons matches the order of the buttons
found on the front panel of the generator. The current status of
the buttons can be checked using the LEDS? query.
Other Required Cmds:
None
Example:
K E Y Y 8 / / T o g g l e c u r r e n t s t a t u s o f
/ / o u t p u t g a t e s