Quantum Data 801GC User Manual
Page 245

6-119
EQUB
EQUalization interval Before vertical sync
pulse
Classification:
Format parameter setting
Command Syntax:
EQUB
Limits:
min = 0
max = number of lines after video and before vertical sync
Query Syntax:
EQUB?
Query Response:
Description:
The EQUB command establishes the width of the equalization
interval before the vertical sync pulse in each field whenever a
serrated & equalized sync type is selected via either ASCT or
DSCT commands and selected via the SSST command. If the
type specified for the selected sync signal is one of the CCIR
types, then the actual equalization interval output by the
generator will be 0.5 lines shorter than the whole number
specified. The EQUB? query returns the current setting of EQUB.
Other Required Cmds:
The FMTU command instructs the generator to use the new
setting. The ALLU command updates hardware to the new setting
and redraws the test image.
Example:
E Q U B 3 / / S e t p r e - e q u a l i z a t i o n t o 3
/ / l i n e s i n b u f f e r
F M T U / / U p d a t e h a r d w a r e t o c u r r e n t
/ / b u f f e r c o n t e n t s
FMTA
ForMaT save As
Classification:
Format memory management
Command Syntax:
FMTA
Limits:
(8 characters minus any extension)
Query Syntax:
None
Description:
The FMTA command saves the current contents of the format
edit buffer using the given name.
Other Required Cmds:
None
Example:
F M T A M Y _ F M T / / S a v e w i t h t h e n a m e
/ / " M Y _ F M T "