Quantum Data 801GC User Manual
Page 263

6-137
HSPD
Horizontal Sync Pulse Delay
Classification:
Format parameter setting
Command Syntax:
HSPD
Limits:
min = 1
max = HTOT - HRES - HSPW
Query Syntax:
HSPD?
Query Response:
Description:
The HSPD command establishes the delay between the leading
edge of blanking and the leading edge of the horizontal sync
pulse. The HSPD? query returns the current setting of HSPD.
Other Required Cmds:
The FMTU command instructs the generator to use the new
setting. The ALLU command updates hardware to the new setting
and redraws the test image.
Example:
H S P D 1 6 / / S e t 1 6 p i x e l p u l s e d e l a y i n
/ / b u f f e r
F M T U / / U p d a t e h a r d w a r e t o c u r r e n t
/ / b u f f e r c o n t e n t s
HSPG
Horizontal Sync Pulse Gate
Classification:
Format parameter setting
Command Syntax:
HSPG
Limits:
0 = OFF
1 = ON
Query Syntax:
HSPG?
Query Response:
Description:
The HSPG command enables and disables the digital horizontal
sync output. The HSPG? query returns the current HSPG mode.
Other Required Cmds:
In order to use digital horizontal sync, digital separate H&V
sync must be selected with the SSST command. The FMTU
command instructs the generator to use the new setting. The
ALLU command updates hardware to the new setting and redraws
the test image.
Example:
H S P G 1 / / E n a b l e H s y n c o u t p u t i n
/ / b u f f e r
F M T U / / U p d a t e h a r d w a r e t o c u r r e n t
/ / b u f f e r c o n t e n t s