Quantum Data 801GC User Manual
Page 217

6-91
ASSG
Analog Sync Signal Gate
Classification:
Format parameter setting
Command Syntax:
ASSG
or
ASSG
Limits:
< mode>
0 = OFF
1 = ON
(0, 0, 0 or 0, 1, 0 only choices on 801GC-ISA)
Query Syntax:
ASSG?
Query Response:
Description:
The ASSG command enables and disables adding composite sync
to all three analog video outputs when analog sync is selected
(see SSST command) and an analog video signal is being generated
(see AVST command). This command can take the place of
sending all three of the individual ASRG, ASGG and ASBG
commands. The ASSG? query returns the current settings of
ASSG.
Other Required Cmds:
The SSST type must be 4, 5, 6 or 7 to output analog sync. The
FMTU command instructs the generator to use the new setting.
The ALLU command updates hardware to the new setting and
redraws the test image.
Example:
A S S G 0 , 1 , 0 / / E n a b l e c o m p s y n c o n g r e e n
/ / i n b u f f e r
F M T U / / U p d a t e h a r d w a r e t o c u r r e n t
/ / b u f f e r c o n t e n t s