83

Troubleshooting

Something is wrong with the sound

General memory pistons don’t work properly

Division memory pistons don’t work properly (C-380)

Symptom

Cause

Response

Page

You hear noise

If there is a cell phone nearby, noise might be heard from the
C-330/C-380 when a call is made or received, or during a call.

Keep the cell phone as far away from the
C-330/C-380 as possible, or turn it off.

Something is wrong with the sound
when you play certain areas of the
keyboard

You’re playing outside the recommended range of pitches for
that voice.

This is not a malfunction.

High notes are folded down by an
octave, or are not sounded.

You have exceeded the speaking range of the pipe.

This is not a malfunction.

Something is wrong with the sound

You’re playing an octave-shifted organ sound.

If an organ sound is octave-shifted, the
sound may be affected by the timing at
which you play the keys or by phase
relationships, but this does not indicate
a malfunction.

p. 68

Pitch is incorrect

The pitch has been transposed.

Cancel the transpose function.

p. 41

Tuning is incorrect.

Adjust the reference pitch.

p. 40

You’ve specified an octave shift and are playing notes outside the
recommended region.

Change the octave shift setting.

p. 68

Sound is distorted or crackly

The [USER/MIDI] coupler volume has been raised excessively.

Lower the [USER/MIDI] coupler volume.

p. 68

The reverb setting is high, and the “Room Type” setting is long.

Reduce the reverb setting, or shorten
the “Room Type” setting.

p. 34
p. 35

The overall volume is excessive.

Use the [Master Volume] knob to lower
the overall volume.

p. 24

Lower notes sound funny, or rattle

If you do not hear these problems through headphones

Performing at high volume may cause resonant vibration in the
organ itself or in objects near the organ.
Fluorescent lights or glass doors in the room may resonate. In
particular, this is more likely to occur with lower notes at higher
volume.

To reduce such resonances, try the
following steps.
• Move the organ 10–15 cm away from

the wall.

• Reduce the volume.
• Move the organ away from the

resonating objects.

If you hear the same problem through headphones

A different cause is likely.

Please contact your dealer or a Roland
customer service center.

Tremulant effect not applied

The tremulant effect will not be applied to USER orchestral
sounds selected by the [USER/MIDI] coupler settings.

This is not a malfunction.

Symptom

Cause

Response

Page

Settings are not switched when you
press a general memory piston

Settings were not stored correctly at the general memory piston.

Store the settings once again.

p. 47

Symptom

Cause

Response

Page

Settings are not switched when you
press a division memory piston

Settings were not stored correctly at the division memory piston.

Store the settings once again.

p. 47