Chapter 3 Problem solving

69

Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis

If you need more help, go to the next section,

“Diagnosing and correcting the

problem” on page 70

.

4

POWER

Indicator

White/On steady

Power indicator—The external DC power is
available to the BIP.

5

CRITICAL

Indicator

Red/On steady

Critical fault indicator—Indicates that a severe
service-affecting condition has occurred that
requires immediate corrective action. Common
causes for this type of fault condition include:

Line card failure

Temperature fault

CPU fault when only one CPU is installed

6

MAJOR

Indicator

Red/On steady

Major fault indicator—Indicates that the system
hardware or software has identified a serious
disruption of service or that an important circuit
failure has occurred.

Common causes for this type of fault condition
include:

CPU fault when two CPUs are installed

Two fan trays are faulty

A power supply circuit breaker has tripped due
to an overcurrent condition

Two power supplies are faulty

7

MINOR

Indicator

Yellow/On steady

Minor fault indicator —Indicates a problem that
does not have a serious effect on customer service,
or a problem in circuits that are not essential to
device operation.

Common causes for this type of fault condition
include:

Shelf alarm cables not installed or not
connected properly.

Alarm module jumpers configured incorrectly.

One power supply is faulty

One fan tray is faulty

Table 4 BIP LEDs and indicators (continued)

Item

Label/Icon

Type

Color/State

Description