Verifying the installation – Nortel Networks 8010co User Manual
Page 62

62
Chapter 2 Installation
312755-G Rev 00
2
To install the shelf alarm cable for a second chassis in the upper shelf:
a
Configure the jumpers on the alarm module to support a second chassis in
the upper shelf as described in
“Accessing the alarm module” on page 30
b
Connect one end of the shelf alarm cable to the J1 connector on the back
of the BIP (
).
c
Connect the other end of the shelf alarm cable to the upper shelf chassis
alarm connector, on the upper shelf chassis.
After successfully installing the shelf alarm cables, go to the next section
.”
Verifying the installation
This section describes how to verify the BIP hardware installation. It includes the
following topics:
•
,” next
•
“Verifying the LEDs” on page 63
•
“Powering off the system” on page 64
Before powering up the system to verify the installation, be sure that:
•
All cables are installed and properly secured.
•
All safety covers, filler panels, and bezels are installed and secure.
•
All tools and installation materials are removed.
•
You notify others working in the area that the system power is about to be
turned on.