National Instruments FP-3000 User Manual
Page 65

Chapter 4
Block Reference
© National Instruments Corporation
4-13
FieldPoint FP-3000 User Manual
Function Name
set_status
Function Syntax
vs_discrete set_status(vs_discrete,
status) OR
vs_float set_status(vs_float, status)
Input
Any symbol that is a value status combination
Purpose
This function sets the status of the input parameter
to the input status and returns the input parameter
with the old value and newly set status.
Return value
vs_discrete
or
vs_float
input parameter with
the old value but new status
Function Name
get_status
Function Syntax
unsigned char get_status(vs_discrete)
OR
unsigned char get_status(vs_float)
Input
Any symbol that is a value status combination
Purpose
This function retrieves the status of the input
parameter and returns it.
Return value
Status of the input parameter
Function Name
to_scaled
Function Syntax
vs_float to_scaled( float valueToScale,
float engUnit0,
float engUnit100)
Input
engUnit0
is the low value of the scale range,
engUnit100
is the high value of the scale range,
and
valueToScale
is the floating point value
(implicitly between 0 and 1) that needs to be scaled
(i.e., 0 <=
valueToScale
<= 1)