3-46 Service Processor

Table 3-35. HC Subcommands (cont’d)

cmd arg1

arg2

arg3

arg4

Description

clear

mmcxy rowz

-

-

Clears the memory bit error counters of ROW.

x” is the physical CELLV Board number (0-3).

y” is the MMC number (0-1) within the CELLV
Board.

z” is the ROW number (0-3).

Each ROW has 3 counters. 3 counters are
cleared at the same time.

[Types of error counters]

Single bit error counter:

Counts in the unit of DIMM in the ROW.

Multi bit counter:

Counts in the unit of the ROW.

This subcommand can be executed in the AC
POWER ON state or DC POWER ON state.

Table 3-36. HC State Display Strings

Displayed String

Description

nonexist

Indicates that a component is defined as non-existent (i.e. the iSP manages a
component as if it does not exist).

INVISIBLE

The iSP manages a component as if it exists, but it does not exist when seen
from the iSP due to failure or other reasons.

Once it is recognized by the iSP (regardless of auto detection or manual setting),
it will be managed as if it exists unless you delete it explicitly using the “delete”
command.

power-off

Indicates that the power supply (DC) is OFF.

For some components, the power supply (DC) becomes ON when AC is
supplied.

power-on

Indicates that the power supply (DC) is ON.

For some components, it is overwritten by the following state display.

offline

Indicates that the power supply (DC) is ON and a component is not configured in
the software (OS or BIOS).

This applies to the CELLV Board, XIC/XBR Board, PCIV/PCIX Unit, and their
subcomponents.

online

Indicates that the power supply (DC) is ON and a component is configured in the
software (OS or BIOS).

This applies to CELLV Board, XIC/XBR Board, PCIV/PCIX Unit, and their
subcomponents.

master

This is valid only for the state display of the ISP-C Board. Always Indicates that
it is operating as the master.

enable

Indicates that the component itself is enabled (used for system operation).