En (environmental information) – NEC 1080Xd User Manual
Page 77
Service Processor 3-27
EN (Environmental Information)
Execution:
This command can be executed in the AC POWER ON or DC POWER state.
Function:
Lists the states of the system’s detected temperature and fan errors, etc. The
components in the DC POWER OFF state are not supervised.
Note:
The EN command can be executed in Normal mode or
Maintenance mode.
Table 3-30. EN Screen
Screen Image
Reference
iSPyz:---> en
---- Power Box/Bay Units -------------------------------------------------- 19:20:57,01/31/2002 ----
state
DPS0
DPS1
DPS2 DPS3 DPS4
DPS5
PBAY00
ON
---
---
PBAY01
ON
---
---
* EXT PBAY10 ON
---
---
ALARM
----------------------------------------------------------------------------------------------------------------------
A
---- Main Chassis FANs ---------------------------------------------------- 19:20:57,01/31/2002 ----
CELL FR0
FF0 FR1 FF1
ALARM
HIGH
HIGH
HIGH
XIC/XBR
FRL
FRR FR2 FF2
ALARM
PCIV0 FM0
FM1 FM2 FM3
ALARM
----------------------------------------------------------------------------------------------------------------------
B
Next page? (n[ext]/e[xit]/CR=next) :
C
---- CELL/XIC/XBR board DD-con/Temp alarm ---------------------- 19:20:57,01/31/2002 ----
state
DD-con
Temp
CELL0
ON
* CELL1
OFF
ALARM
* CELL2
NORESP
*
CELL3
OFF
ALARM
*
XIC
OFF
ALARM
* XBR
NORESP
----------------------------------------------------------------------------------------------------------------------
D
---- PCIX-BOX DD-con/Temp/FAN alarm ------------------------------ 19:20:57,01/31/2002 ----
state
DD-con
Temp
FAN
Local/Remote
*
PCIX0(V)
ON ALARM
---
*
PCIX1(F) OFF
ALARM
ALARM Remote
*
PCIX2(F)
ON ---
ALARM
Local
*
PCIX3(F)
OFF --- ALARM
Remote
----------------------------------------------------------------------------------------------------------------------
E