3-44 Service Processor
Table 3-35. HC Subcommands (cont’d)
cmd arg1 arg2
arg3 arg4 Description
cellx
on|off
-
-
Turns on/off the LED of the CELLV Board.
“x” is the physical CELLV Board number (0-3).
pcixx
on|off
-
-
Turns on/off the LED of the PCIV/PCIX Unit.
“x” is the number of PCIV/PCIX Unit
(0-3).
When the PCIV is specified, all alarm LEDs are
turned on.
pcixx slotnn
on|off
-
Turns on/off the LED of the PCI slot in the
PCIV/PCIX Unit. Slot number printed at the back
side of the Unit must be designated.
“x” is the number of PCIV/PCIX Unit
(0-3).
“nn” is the slot number printed at the back side
of the Unit.
gxbxy
busA|
busB
slotn
on|off
Turn on/off the LED of the PCI slot in the
PCIV/PCIX Unit according to physical control
number.
“x” is the PCIV/PCIX Unit number
(0-3).
“y” is the GXB number (0-3) in the PCIV /PCIX
Unit.
“n” is the slot number (0-3) in the unit of GXB
bus.
led
(cont’d)
fann
on|off
-
-
Turn on/off the LED of the Fan Unit in the Main
Chassis. “n” is the Fan Unit number.
loc
-
-
-
-
Used to specify location information manually.
Displays Help for “loc” when the argument is
omitted or an error is made.
This subcommand can be executed when all
partitions are in the DC POWER OFF state.
main
d
-
-
Specifies the location of the Main Chassis.
“d” is the position of the lower edge of the
chassis from the bottom of the cabinet in
decimal (0-63) by using the EIA unit.
(1 EIA unit = 44.45mm)