beautypg.com

Checking failure – NEC 1080Xd User Manual

Page 46

background image

2-18 System Operation

Table 2-2. Formats Conforming to EDD3.0 Specification

Path Display

Description

Acpi(PNP0A03, X)

Indicates that the device is installed under the PCI host bus.

X: PCI host bus bridge number (starting with 0).

Pci(D|F)

Indicates PCI installation information of the device.

D: PCI device number (Device numbers 2 – 5 correspond to
slot numbers 1 – 4.)

F: PCI function number.

Scsi(Pun0,Lun0)

Installation location of the SCSI device (disk) connected to
the SCSI card.

HD(Part1,SigFF050000)

SCSI disk drive information.

See the following example and Table 2-3 for device path formats for devices
that do NOT conform to EDD3.0 specification:

Example: SCSI cards and fixed disks installed on the PCI bus:

VenHw(Unknown Device:80)/HD(Part1,Sig6D5319DE)

Table 2-3. Formats for Devices Not Conforming to EDD3.0 Specification

Path Display

Description

VenHw(Unknown Device:80)

Example: The device does not conform to EDD3.0
specification.

80: a consecutive number (called a drive number) assigned
to the disk under the SCSI card by the system BIOS.

The drive numbers are as follows:

80 or higher: fixed disk drive

9F: DVD-ROM drive

HD(Part1,Sig6D5319DE)

SCSI disk drive information.

Checking Failure

When a failure is detected in the system, it can be checked in the Virtual System
Operator Panel (SOP) on the SP console. Virtual SOP provides the following
information:

!

Partition configuration of the system

!

Failure information.

For more information about Virtual SOP, see “Virtual SOP” in Chapter 3.