Service Processor 3-45

Table 3-35. HC Subcommands (cont’d)

cmd arg1 arg2

arg3 arg4 Description

pbayxy

d h -

Specifies the location and height of the Power
Bay Unit in the cabinet.

x” is the unit ID number.

1: Power Bay Unit
0: Not allowed

y” is the ID number. (0) must be specified.

d” is the position of the lower edge of the unit in
decimal (0-63) by using the EIA unit.
(1 EIA unit = 44.45mm)

h” is the height of the unit (3).

loc
(cont’d)

pcixx

c d

Specifies the location and height of the PCIX
Unit in the cabinet.

x” is the PCIX Unit number (1-3).

c” must be (1).

d” is the position of the lower edge of the unit in
decimal (0-63) by using the EIA unit.
(1 EIA unit = 44.45mm).

check

-

-

-

-

Checks the current configuration information
from the following points:

Presence of units whose location information
is not entered

Presence of “DISABLE” components

Presence of “INVISIBLE” units

Configuration violating the installation
restrictions

Configuration with penalty in
performance/RAS.

This subcommand can be executed in the AC
POWER ON state or DC POWER ON state.