Monitoring and Testing

4-27

3166-A2-GB20-10

November 1998

5. From the Send screen, press the Function key that corresponds to the

interface for which you want to send a test pattern. (NET does not appear for
the 511 pattern.)

F1

Send:

Name

NET

Prt1

F2

F3

The Test Started screen appears.

F1

Send:

Name and Dest

Test Started

F2

F3

If the DSU/CSU is already sending the test pattern you selected, the
message Already active appears. If you select a different pattern than one
the DSU/CSU is already sending, the message Invld Test Combo appears.

Monitoring Test Patterns

Use the Monitor command to monitor a QRSS test pattern over all the channels
on the network interface, or to monitor QRSS or 511 test patterns on the channels
allocated to an individual port.

This command provides the number of errors detected in the test pattern
(5 digits, maximum 99999).

"

Procedure

To monitor a QRSS or 511 test pattern:

1. From the top-level menu screen, select Test.

2. From the Test screen, select Ptrns.

F1

Test:
Rlpbk Lpbk

Ptrns

F2

F3