beautypg.com

Technical specifications, Overview, Appendix b – Paradyne 3166 CSU User Manual

Page 101

background image

B-1

3166-A2-GB20-10

November 1998

Technical Specifications

B

Overview

The technical specifications for the 3166 DSU/CSU are listed in Table B-1. The
fan module cooling requirements for the 3000 Series Carrier are provided in the
COMSPHERE 3000 Series Carrier Installation Manual.

Table B-1.

ACCULINK Model 3166 DSU/CSU Technical Specifications (1 of 2)

Specifications

Criteria

POWER REQUIREMENTS
Sixteen 3166 DSU/CSUs with SDU,
SDCP, and fan module:

115 Vac power supply

– 48 Vdc power supply

90 to 132 Vac, 60 Hz

±

3

(2.4 amp, 215 watts at 115 Vac)

ā

60 to –

ā

40 Vdc (4.7 amps maximum)

POWER CONSUMPTION

6.5 watts per circuit card

NETWORK T1 INTERFACE
Physical Interface (USA)
Physical Interface (Canada)
Framing Format
Coding Format
Line Build-Out (LBO)
ANSI PRM
Bit Stuffing
Yellow Alarm Generation

RJ48C
CA81A (T1 with adapter cable)
D4, ESF
AMI, B8ZS
0.0 dB, –7.5 dB, –15 dB, –22.5 dB
Selectable
FCC Part 68, AT&T TR 62411
Selectable

LOOPBACKS
Standard

Additional

AT&T TR 54016, AT&T TR 62411,
ANSI T1.403.1989

RLB (Repeater Loopback), V.54 Loop 2 and
Loop 3, ANSI T1.403 Annex B Fractional T1
Loopback