beautypg.com

Paradyne 3166 CSU User Manual

Page 74

background image

Monitoring and Testing

4-8

3166-A2-GB20-10

November 1998

Table 4-3.

Performance Registers (2 of 3)

Register

Totals Description

Interval Description

SES

The number of severely errored
seconds for the current interval. A
severely errored second is any
second with 320 or more CRC
errors, or any second with one or
more OOF events. The maximum
is 900 seconds.

The total number of severely
errored seconds for the previous

x

hours, where

x is 24 hours for

aggregate performance and 8
hours for port performance.

BES

The number of bursty errored
seconds for the current interval. A
bursty errored second is any
second with more than one, but
less than 320, CRC errors. The
maximum is 900 seconds.

The total number of bursty errored
seconds for the previous

x hours,

where

x is 24 hours for aggregate

performance and 8 hours for port
performance.

LOFC

The loss of frame count for the
current interval. This is a count of
the number of times that an LOF is
declared. The maximum count is
255.

The total loss of frame count for the
previous

x hours, where x is

24 hours for aggregate
performance and 8 hours for port
performance.

CSS
(Not valid
for Port
registers.)

The number of controlled slip
seconds for the current interval.

The total number of controlled slip
seconds for the previous

x hours,

where

x is 24 hours for aggregate

performance and 8 hours for port
performance.

This manual is related to the following products: