Table 4-4, For enterprise-specific traps. these, Option – Paradyne 3166 CSU User Manual
Page 79: Table 4-5, Defines traps for each interface
Monitoring and Testing
4-13
3166-A2-GB20-10
November 1998
Table 4-4.
Enterprise-Specific Trap Definitions
Trap Value
Event
enterpriseClockFail(1)
The currently configured master clock source has failed.
enterpriseSelfTestFail(2)
A DSU/CSU hardware failure is detected at self-test. This
trap is generated after DSU/CSU initialization.
enterpriseDeviceFail(3)
An internal DSU/CSU failure is detected by the operating
software.
enterpriseTestStart(5)
A test is initiated.
enterpriseConfigChange(6)
A configuration option is changed.
enterpriseTestClear(105)
A test is concluded.
Table 4-5.
SNMP Trap per Interface
Interface
Trap Meaning
T1 Network
Up = No alarm or test conditions.
Down = Alarm or test conditions.
Synchronous Data Port
Up = No test conditions, the port is assigned to a network
interface, and both CTS and DSR are ON.
Down = Test conditions, the port is unassigned, or either
CTS or DSR is off.