Monitoring and Testing

4-13

3166-A2-GB20-10

November 1998

Table 4-4.

Enterprise-Specific Trap Definitions

Trap Value

Event

enterpriseClockFail(1)

The currently configured master clock source has failed.

enterpriseSelfTestFail(2)

A DSU/CSU hardware failure is detected at self-test. This
trap is generated after DSU/CSU initialization.

enterpriseDeviceFail(3)

An internal DSU/CSU failure is detected by the operating
software.

enterpriseTestStart(5)

A test is initiated.

enterpriseConfigChange(6)

A configuration option is changed.

enterpriseTestClear(105)

A test is concluded.

Table 4-5.

SNMP Trap per Interface

Interface

Trap Meaning

T1 Network

Up = No alarm or test conditions.

Down = Alarm or test conditions.

Synchronous Data Port

Up = No test conditions, the port is assigned to a network
interface, and both CTS and DSR are ON.

Down = Test conditions, the port is unassigned, or either
CTS or DSR is off.