beautypg.com

Paradyne 3166 CSU User Manual

Page 75

background image

Monitoring and Testing

4-9

3166-A2-GB20-10

November 1998

Table 4-3.

Performance Registers (3 of 3)

Register

Totals Description

Interval Description

StEvnt
(Only valid
for User
registers.)

The status events register records
whether one or more of the
following events have occurred at
least once during the interval. The
event is identified by a letter as
follows:

Y – A Yellow Alarm signal has

been received on the network
interface.

L – Loss Of Signal has occurred

on the DTE Drop/Insert
(DSX-1) interface.

E – The Excessive Error Rate

threshold has been
exceeded.

F – A Frame Synchronization Bit

Error has been detected.

If none of these events occurred
during the interval, StEvnt=none
will be displayed.

N/A

Complete
(Only valid
for far-end
port
registers.)

Bad line conditions or loopback
tests may prevent far-end port
statistics from reaching the
DSU/CSU. This field indicates
whether the 15-minute interval
contains 900 seconds of statistics.
If one or more seconds of far-end
statistics are missing, this field will
display Complete=No, otherwise it
will display Complete=Yes. This
field is only displayed when Far is
selected from the Prt1 screen.

N/A

This manual is related to the following products: