SNMP MIB Objects

E-20

3166-A2-GB20-10

November 1998

H

testSendV54Up – Sends a V54 up code to the remote unit. Only supported
for the data ports.

H

testSendV54Down – Sends a V54 down code to the remote unit. Only
supported for the data ports.

H

testSendFT1Up – ends a FT1 up code to the remote unit. Only supported for
the data ports.

H

testSendFT1Down – Sends a FT1 down code to the remote unit. Only
supported for the data ports.

Where these object identifiers are defined as follows:

H

testLoopDTLB – OBJECT IDENTIFIER ::= [wellKnownTests 2]

H

testMonQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 3]

H

testMon511 – OBJECT IDENTIFIER ::= [wellKnownTests 4]

H

testSendQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 5]

H

testSend511 – OBJECT IDENTIFIER ::= [wellKnownTests 6]

H

testSendV54Up – OBJECT IDENTIFIER ::= [wellKnownTests 7]

H

testSendV54Down – OBJECT IDENTIFIER ::= [wellKnownTests 8]

H

testSendFT1Up – OBJECT IDENTIFIER ::= [wellKnownTests 9]

H

testSendFT1Down – OBJECT IDENTIFIER ::= [wellKnownTests 10]

Generic Interface Test Table – “ifExtnsTestResult” Object
(ifExtnsTestEntry 5)

This object contains the result of the most recently requested test. Only the
following values are supported by the DSU/CSU.

H

none(1) – No test currently active.

H

inProgress(3) – A test is currently in progress.

H

notSupported(4) – The requested test is not supported.

H

unAbleToRun(5) – The requested test cannot run due to the state of the unit.