Monitoring and Testing

4-18

3166-A2-GB20-10

November 1998

Sending a V.54/ANSI FT1 Activation/Deactivation

"

Procedure

To send a V.54 or ANSI FT1 Activation or Deactivation loopback sequence to the
far-end DSU/CSU:

1. From the top-level menu screen, select Test.

2. From the Test screen, select Rlpbk.

F1

Test:
Rlpbk Lpbk

Ptrns

F2

F3

3. From the Rem Loopback screen, press the function key that corresponds to

the specific loopback test you want to perform. Use the scroll keys, if
necessary.

F1

Rem Loopback:
LLBUP LLBDN 54UP

F2

F3

The 54UP, 54DN, FT1UP, and FT1DN commands send the requested
sequence out the network interface on the DS0 channels allocated to Port 1.

4. From the Rem Loop screen, press the desired function key to select the

specific port. Use the scroll keys, if necessary.

After you select a port, the sequence is sent to the far-end DSU/CSU. During
this time, Sending appears on Line 2 of the LCD, followed by Command
Complete
when the sequence is complete.

During the Sending message, you can press the

and

keys without

affecting transmission of the loopback sequence.