Paradyne 3166 CSU User Manual
Page 161
SNMP MIB Objects
E-23
3166-A2-GB20-10
November 1998
Table E-1.
SNMP MIB to Front Panel Command Cross-Reference (2 of 4)
Front Panel Command
SNMP MIB Object
Stat–>Tstat
LLB Test Active
PLB Test Active
RLB Test Active
DCLB on Port1
DTLB on Port1
1–8 Test Active
QRSS Test Active
QRSS on Port1
511 on Port1
Monitoring QRSS
Mon QRSS, Port1
Mon511, Port1
Read:
dsx1LineLoop from dsx1LoopbackConfig for Net T1
dsx1PayloadLoop from dsx1LoopbackConfig for Net T1
dsx1PayloadLoop from dsx1LoopbackConfig for Port1
testFullDuplexLoopback from IfExtnsTestType for Port1
testLoopDTLB from IfExtnsTestType for Port 1
dsx1SendOtherTestPattern from dsx1SendCode for Net T1
dsx1SendQRS from dsx1SendCode for Net T1
testSendQRSS from IfExtnsTestType for Port 1
testSend511 from IfExtnsTestType for Port 1
testMonQRSS from ifExtnsTestType for Net T1
testMonQRSS from ifExtnsTestType for Port 1
testMon511 from ifExtnsTestType for Port 1
Stat–>LED–>Prtn:
DTR
CTS
RTS
Read:
rs232InSigState from rs232InSigName == dtr
rs232outSigState from rs232OutSigName == ctr
rs232InSigState from rs232InSigName == rts
Stat–>ID:
Ser
Mod
SRev
HRevCCA1
HRevCCA2
Read the sysDescr object from the System Group
Test–>Rlpbk–>LLBUP
Set dsx1SendCode to
dsx1SendLineCode
Test–>Rlpbk–>LLBDN
Set dsx1SendCode to
dsx1SendResetCode
Test–>Rlpbk–>54UP–>Prt1
Set IfExtnsTestType for Port 1
to testSendV54Up
Test–>Rlpbk–>54DN–>Prt1
Set IfExtnsTestType for Port 1
to testSendV54Down
Test–>Rlpbk–>FT1UP–>Prt1
Set IfExtnsTestType for Port 1
to testSendFT1UP
Test–>Rlpbk–>FT1DN–>Prt1
Set IfExtnsTestType for Port 1
to testSendFT1Down
Test–>Lpbk–>LLB
Test–>Lpbk–>Abort–>LLB
Set dsx1LoopbackConfig for Net T1 to
dsx1LineLoop
Set dsx1LoopbackConfig for Net T1 to
dsx1NoLoop
Test–>Lpbk–>PLB
Test–>Lpbk–>Abort–>PLB
Set dsx1LoopbackConfig for Net T1 to
dsx1PayloadLoop
Set dsx1LoopbackConfig for Net T1 to
dsx1NoLoop
Test–>Lpbk–>RLB
Test–>Lpbk–>Abort–>RLB
Set dsx1LoopbackConfig for Port1 to
dsx1PayloadLoop
Set dsx1LoopbackConfig for Port1 to
dsx1NoLoop