Resetting performance registers – Paradyne 3166 CSU User Manual
Page 76
Monitoring and Testing
4-10
3166-A2-GB20-10
November 1998
Resetting Performance Registers
You can reset the performance registers via the ClrReg command in the Control
branch of the front panel menu.
"
Procedure
To clear the performance registers:
1. From the top-level menu screen, press the
key until the Ctrl selection
appears on the screen.
2. Select Ctrl.
3. From the Control screen, press the
key until the ClrReg selection
appears on the screen.
4. Select ClrReg.
F1
Control:
Rel
LED
ClrReg
F2
F3
5. From the Clear Prf Regs screen, press F1 to clear the User registers.
F1
Clear Prf Regs:
User
Prt1
F2
F3
If you selected User, the User performance registers are cleared, all
accumulators are reset to zero, and all status registers are cleared. The
current interval timer, the number of valid intervals count, and the total
24-hour counts are reset to zero. The Command Complete message then
appears.