beautypg.com

Printer control, Ribbon end point, Open platen @ bof (bottom of form) – Printronix H-SERIES P7000 User Manual

Page 99

background image

Page Format Submenu

99

PRINTER CONTROL

Ribbon End Point

This parameter adjusts the point at which the system will declare the ribbon
as being expended. The life count will always be from 100% to 0%, but if a
darker setting is selected 0% will be reached more quickly. If a lighter setting
is selected, the system will extend the time it takes to reach 0%. The range of
values are as follows:

Normal

Darker +1 through Darker +6

Lighter -1 through Lighter -10
(Lighter -7 is the default)

NOTE: This value can be adjusted at any time and the display will

automatically adjust to show the correct percentage relative to the
new end point.

Open Platen @ BOF (Bottom of Form)

Some special forms have perforation areas that are too thick to pass through
the print station. This parameter, when enabled, opens and closes the platen
when the perforations move across the platen. When enabling this parameter,
you must set the forms length to match the physical distance between
perforations.

PRINTER

CONTROL

(from page 50)

Unidirectional

Display

Language

Open Platen

@BOF

Accented

Char

Tear Bar

Dist.

Disable*
Enable

English*

Disable*
Enable

Standard*
Tall

7.46 inches.*
(4.5 - 10.5)

* = Factory Default

1

Available only for P7000 pedestal model

Ribbon End

Point

Darker +6
Darker +5
Darker +4
Darker +3
Darker +2
Darker +1
Normal
Lighter -1
Lighter -2
Lighter -3
Lighter -4
Lighter -5
Lighter -6
Lighter -7*
Lighter -8
Lighter -9
Lighter -10

View

Function

1

Disable*
Enable

PRINTER CONTROL