Printronix H-SERIES P7000 User Manual
Page 155
Fault Messages
155
H01: PCI J12
See User Manual
No
The controller board is not
communicating with the PCI
card in PCI slot J12. This
could indicate a bad PCI
card, poor connection, or
problem in the PCI bus.
Contact your authorized service
representative.
1
H02: PCI J13
See User Manual
No
The controller board is not
communicating with the PCI
card in PCI slot J13. This
could indicate a bad PCI
card, poor connection, or
problem in the PCI bus.
Contact your authorized service
representative.
1
Half Speed Mode
No
Status message: The
controller samples the
operating temperature of key
components of the print
mechanism. When higher
than normal temperatures
are sensed, the print speed
is automatically reduced by
50% and the message sent
the LCD. When the
components cool down, the
print speed returns to 100%
and the message clears.
No action is required. If the
message appears often, contact
your authorized service
representative.
1
HAM. COIL OPEN*
No
Hammer Coil Open.
Electrical malfunction of one
or more hammer coils.
Contact your authorized service
representative.
1
HAMMER COIL BAD*
#, #, #, ...etc
No
Hammer coil # failed current
test at power up.
Contact your authorized service
representative.
1
HAMMER SHORT*
See User Manual
No
Electrical malfunction of one
or more hammer coils.
Contact your authorized service
representative.
1
HB NOT INSTALLD*
No
Hammer Bank Not Installed.
Self-test routines do not
detect hammer coils at
printer start-up.
Contact your authorized service
representative.
1
HMR BANK FAN FLT
Yes
Sensors cannot detect
current in fan circuit.
Check that fan cable is
connected. Check for
obstruction of vents and fan
airway; remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on
the printer. If this message
recurs, contact your authorized
service representative.
1
Table 12. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation
Solution