Printronix H-SERIES P7000 User Manual
Page 153

Fault Messages
153
ERROR: PROGRAM
NOT COMPATIBLE
Yes
The printer is not compatible
with the downloaded
program.
Use the correct emulation
software options(s) for this
printer model.
ERROR: PROGRAM
NOT VALID
Yes
The printer does not see a
program in flash memory.
There is no program in printer
memory. Download the
emulation.
ERROR: SECURITY
KEY NOT DETECTED
No
The security key is not
present or failed.
Contact your authorized service
representative.
1
ERROR: SHORT AT
ADDRESS XXXX
No
Hardware failure in SDRAM
or controller circuitry.
Contact your authorized service
representative.
1
ERROR: WRITING TO
FLASH
No
Hardware or software fault in
flash memory.
Contact your authorized service
representative.
1
ERROR: WRONG
CHECKSUM
No
The printer received the
complete program but the
checksum did not match.
The data may have been
corrupted during
downloading.
Contact your authorized service
representative.
1
ERROR: WRONG
OEM
No
The SPX inserted in the
debug port is not intended
for this model printer or this
OEM.
Contact your authorized service
representative.
1
ERROR: WRONG
PRINTER TYPE
No
The SPX inserted in the
debug port is not intended
for this model printer or this
OEM.
Contact your authorized service
representative.
1
ETHERNET ADAPTER
BEING INITIALIZED
N/A
Status message indicating
that the ethernet interface is
processing the boot
procedure.
No action is required.
ETHERNET
DETECTED
N/A
Status message indicating
that the Network Interface
Card has established
connection.
No action is required.
ETHERNET
INITIALIZING
No
Status message: the internal
Network Interface Card is
processing the boot
procedure. (May occur with
older versions of microcode.)
No action is required.
Table 12. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation