Printronix H-SERIES P7000 User Manual
Page 159
Fault Messages
159
PLAT INV PARM*
No
Platen Invalid Parameter.
Firmware error on controller
board.
Contact your authorized service
representative.
1
PLAT INV STATE*
No
Platen Invalid State.
Firmware error on controller
board.
Contact your authorized service
representative.
1
PLEASE WAIT...
RESET IN
PROGRESS
N/A
Status message: the printer
finished loading the program
into flash memory and is
automatically resetting itself.
No action is required.
POWER SUPPLY HOT
Yes
Power supply sensors report
high temperatures.
Check printer environment. If hot
or dusty, relocate printer.
Contact your authorized service
representative if this occurs
frequently.
1
PRINTER HOT
Yes
This message indicates
internal temperatures over
60° Celsius (140°
Fahrenheit).
Check printer environment. If hot
or dusty, relocate printer.
Contact your authorized service
representative if this occurs
frequently.
1
PRINTER UNDER
REMOTE CONTROL
No
Status message: The printer
is under the control of
PrintNet Enterprise (PNE)
remote management
software.
No action is required.
PROTECTED INSTR*
No
Protected Instruction.
Firmware error on controller
board.
Contact your authorized service
representative.
1
PWR SUPP VOLT *
No
Power Supply Voltage. The
power supply has failed.
Replace power supply board.
QUEUE OVERRUN
No
In CT twinax emulation, the
print buffer has overflowed.
Contact your authorized service
representative.
1
REMOVE USED SPX
THEN PRESS ENTER
No
Status message: An SPX is
depleted because it has
successfully reprogrammed
the security key on the
controller board.
Contact your authorized service
representative.
1
RESTORING BOOT
CODE
No
Normal download
initialization message.
No action is required.
Table 12. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation
Solution