Alarms
The Alarms tab has the following sub-tabs:
•
•
•
•
Groups
Alarm groups can be enabled or disabled via the Web interface. Place a check mark in the box provided to enable a
specific group. Remove the check mark from the box to disable the alarms. Alarm severity levels are as follows:
• Critical alarms will often result in severe disruption in network activity or an automatic reboot of the AP.
• Major alarms are usually activated due to a breach in the security of the system. Clients cannot be authenticated
because an attempt at unauthorized access into the AP has been detected.
• Informational alarms provide the network administrator with some general information about the activities the AP is
performing.
Configuration Trap Group
Trap Name
Description
Severity Level
oriTrapDNSIPNotConfigured
DNS IP address not configured
Major
oriTrapRADIUSAuthenticationNotConfigured
RADIUS Authentication not configured
Major
oriTrapRADIUSAccountingNotConfigured
RADIUS Accounting not configured
Major
oriTrapDuplicateIPAddressEncountered
Another network device with the same IP address
exists
Major
oriTrapDHCPRelayServerTableNotConfigured The
DHCP relay agent server table is empty or
not configured
Major
oriTrapVLANIDInvalidConfiguration
A VLAN ID configuration is invalid
Major
oriTrapAutoConfigFailure
Auto configuration failed
Minor
oriTrapBatchExecFailure
The CLI Batch execution fails for the following
reasons:
• Illegal Command is parsed in the CLI Batch
file
• Execution error is encountered while
executing CLI Batch file
• Bigger file size than 100 Kbytes
Minor
oriTrapBatchFileExecStart
The CLI Batch execution begins after file is
uploaded
Minor
oriTrapBatchFileExecEnd
The execution of CLI Batch file ends.
Minor