Application interfaces – Laser beta lasermike LS8000-3 User Manual
Page 71

LaserSpeed 8000-3 Instruction Handbook
Interfacing with the LS8000-3
Part No. 93463 / Drawing No. 0921-01561
Page 71 of 221
Revision A (Sep 2007)
Application Interfaces
Light Stack Interface
The LS8000-3 User Scaleable Pulse Outputs and Index Pulse output can be
reconfigured and connected to a light stack in order to indicate the current
state of the laser in order to warn people in the area of laser radiation. The
pulse outputs can be reconfigured into a light stack interface by setting the
following settings:
Setting
Value
Command
Index Pulse Output Function
Light Stack (Green)
#9
User Scaleable Pulse Output
Configuration
Light Stack (Yellow/Red)
$L9
The outputs can then be connected to solid state relays in order to drive a light
stack as shown below. This will provide a contact closure for each lamp. The
maximum current that can be driven by this interface will depend on the
selected relay.