Kaveraging time, Ouser update rate – Laser beta lasermike LS8000-3 User Manual
Page 135

LaserSpeed 8000-3 Instruction Handbook
RS-232/RS-422 Communication
Part No. 93463 / Drawing No. 0921-01561
Page 135 of 221
Revision A (Sep 2007)
Response: 3225,4538
Meaning:
Internal Temperature: 32.25ºC
Maximum Internal Temperature: 45.38ºC
K
Averaging Time
K
Read
Response
Format:
K
Set
is an integer from 0 to 2047 that indicates the number of milliseconds of averaging for
the LS8000-3's measurements. This value should be set to 0 by default. This enables
automatic averaging.
The LS8000-3 generates a new velocity and length measurement, updates the pulse output
frequencies, and updates the analog output every 1ms. This setting controls the length of
the moving average used to calculate the 1ms reading.
O
User Update Rate
M
Read
Response
Format:
M
Set
is an integer from 0 to 2047 that specifies, in milliseconds, how often the LS8000-3
transmits data over the serial/Ethernet port. For example, an O setting of 32 would cause
the LS8000-3 to transmit data every 32 milliseconds. Some typical update rates are:
O
Rate
Command
4 ms
Fast
O4
32 ms
Medium O32
100 ms
Slow
O100
Depending on the baud rate, when using fast update rates, it may not be possible for the
LS8000-3 to complete transmission of an entire measurement update before it is time to
transmit the next one. If this occurs, the late measurement will not be transmitted. See the
Serial Real-Time Data Timing section for further details.