H high speed pulse output configuration, Lhigh speed pulse rate – Laser beta lasermike LS8000-3 User Manual
Page 144

LaserSpeed 8000-3 Instruction Handbook
RS-232/RS-422 Communication
Part No. 93463 / Drawing No. 0921-01561
Page 144 of 221
Revision A (Sep 2007)
The output will clear when the length reaches 200ft, and the Index Pulse triggers. See the
Index Pulse & Length Thresholds
section for timing details.
$H
High Speed Pulse Output Configuration
$H
Read
Response
Format:
$H
Set
is an integer that specifies the function of the High Speed Pulse Output. The various
outputs were described previously in the Index Pulse Output Function description.
Pulse Output Function
Value
Phase A
Phase B
0
Default (High Speed Pulse Outputs)
1
System Ready
Material Present
2 System
Ready Valid
3
System Ready
QF Pulse Output
4
System Ready
QF Warning Output
5
System Ready
Shutter Open
6
System Ready
Laser On
7
System Ready
Thermostat Output
8 Valid
Thermostat
Output
9
Pulse Phase A
Sync Output
Note: Some of the above outputs were previously described under the Index Pulse Output
Function setting.
Sync Output
Gauge-Gauge Synchronization Output that can be connected between multiple gauges in
order to synchronize measurements. See the
Gauge-Gauge Synchronization
section for
details.
L
High Speed Pulse Rate
L
Read
Response
Format:
L
Set