Tv read one line of tt data, Stop real-time output – Laser beta lasermike LS8000-3 User Manual
Page 159

LaserSpeed 8000-3 Instruction Handbook
RS-232/RS-422 Communication
Part No. 93463 / Drawing No. 0921-01561
Page 159 of 221
Revision A (Sep 2007)
79,+000000741,000012344,15,63,3125
79,+000000864,000012342,15,63,3125
These readings indicate the length increasing from +0.370 to 0.864, with a velocity near
+12.345, a Quality Factor of 15, Status of 63, and an internal gauge temperature of 31.25ºC.
TV
Read One Line of TT Data
TV
Data Output Command
Response Format: Variable (Depends on TT Value)
This command will cause the LS8000-3 to transmit one line of data in the format configured
by the TT command. See the TT command for details.
.
Stop Real-time Output
.
Command
This command stops the LS8000-3 from sending real-time measurement data. This
command has the same effect as just sending a