Prerequisites for mbl and pbl calibration, Printing a pbl test, Prerequisites for mbl and pbl calibration -4 – Kodak RP 30 User Manual
Page 136: Printing a pbl test -4
Operator’s Guide
Prerequisites for MBL and PBL Calibration
Before printing the MBL and PBL calibration:
1. Check that there are no print orders pending.
2. Use the Information (i) button to check that no paper is in the paper transport of
the printer and the paper processor for the MBL and the PBL calibration.
3. Check that there is enough paper in the magazine for the two tests
(approximately 3 m [40 in.]).
4. Check that the chemical solutions are at nominal temperature.
Printing a PBL Test
When it is necessary to print a PBL test, follow these instructions.
1. Touch:
•
Test
•
Start PBL
2. Select the paper configuration for which the PBL test is to be printed.
3. Touch
PBL to print the test.
4. Enter in the next screen:
•
Emulsion no. (only for information, not assessed)
•
Tolerance: Step width 0.1 mm
Possible input of the manually measured deviation of the paper from the coded
width (useful for border prints).
5. Activate / deactivate with Laser point.
6. Touch
Start.
5-4