MVOPT=n

Modbus Variant Option: Sets various behavioral options when 
dealing with a Modbus‐variant protocol. This parameter is 
used when the when MD is set to hex 63. Cannot be configured 
in AceManager.

n=0 : No special action (Default).

n=1 : Skip leading zeroes in Modbus packets.

MVTYP=n

Modbus Variant Type: The data‐type of the RTU ID in a 
modbus‐variant protocol. This parameter is used to define the 
data‐type of the RTU ID in Modbus‐like protocol data packets. 
This parameter is used when MD is set to 63. 

n=0 : Binary (Default) 

n=1 : ASCII Hex

n=2 : ASCII Decimal

RKEY=n

Enable/disable MDS Radio transceiver keying. Radio keying is 
designed to assert CTS when a packet is received, delay the 
time as specified, send the data out the serial port, wait the 
same amount time, drop CTS. This way, the CTS signal can be 
used to key a transmitter on and give it time to reach its power 
level before data is sent to it. Delay interval is specified in S221.

n=0 : Off (Default).

n=1 : On.

Addr List

Figure 1-16: AceManager : Addr List